Small and medium-sized enterprises are

00:00:19.316 --> 00:00:21.783
already investing in generating renewable

00:00:21.783 --> 00:00:25.783
energy with photovoltaics, electromobility

00:00:25.783 --> 00:00:28.566
and sustainable heat generation.

00:00:28.766 --> 00:00:30.666
For example, through heat pumps,

00:00:30.666 --> 00:00:33.016
a certain independence from

00:00:33.016 --> 00:00:35.933
fluctuating energy prices is achievable.

00:00:36.666 --> 00:00:39.833
Often, devices from different manufacturers

00:00:39.833 --> 00:00:41.550
are used each with its own,

00:00:41.550 --> 00:00:44.200
often cloud-based control system.

00:00:44.833 --> 00:00:47.066
Without the support of an energy manager

00:00:47.066 --> 00:00:49.650
and facility management, the use of

00:00:49.650 --> 00:00:52.366
different systems often makes it difficult

00:00:52.366 --> 00:00:55.600
to coordinate the individual systems with one another.

00:01:01.416 --> 00:01:04.116
In the event of a grid power failure,

00:01:04.116 --> 00:01:06.966
the individual systems cannot synchronize

00:01:06.966 --> 00:01:09.883
and plan the sensible use of stored energy.

00:01:10.883 --> 00:01:14.100
Energy-intensive processes continue,

00:01:14.250 --> 00:01:17.516
while secondary storage units cannot be used.

00:01:19.233 --> 00:01:21.333
If the energy in the central energy

00:01:21.333 --> 00:01:23.100
storage is depleted, the system can

00:01:24.000 --> 00:01:26.683
no longer be supplied with electricity.

00:01:27.500 --> 00:01:29.800
This results in a blackout too.

00:01:30.916 --> 00:01:33.350
If there is sufficient energy production

00:01:33.350 --> 00:01:34.933
from the photovoltaics,

00:01:34.933 --> 00:01:37.866
power generation can be resumed.

00:01:38.866 --> 00:01:40.566
Without the ability to focus

00:01:40.566 --> 00:01:42.133
on essential processes, however,

00:01:42.583 --> 00:01:45.083
this cannot necessarily be ensured.

00:01:49.416 --> 00:01:51.000
By adding coupling modules

00:01:51.000 --> 00:01:52.500
to the core components of energy

00:01:52.500 --> 00:01:54.583
production and energy consumption,

00:01:54.583 --> 00:01:57.383
as well as to the energy storage units,

00:01:57.383 --> 00:02:00.850
the previously independent systems are networked.

00:02:01.816 --> 00:02:04.666
The local radio standard, LoRaWAN,

00:02:04.666 --> 00:02:06.500
is used to enable a communication

00:02:06.500 --> 00:02:09.850
channel independent of mobile networks.

00:02:13.416 --> 00:02:15.633
By installing a local energy steering

00:02:15.633 --> 00:02:18.516
and management system (ESMS),

00:02:18.516 --> 00:02:20.816
the system becomes autonomous,

00:02:20.816 --> 00:02:23.283
and thereby island-capable,

00:02:23.283 --> 00:02:25.533
since all decisions for controlling the energy

00:02:25.533 --> 00:02:27.666
flows are made locally.

00:02:28.416 --> 00:02:30.950
Synchronization with the cloud is only

00:02:30.950 --> 00:02:33.966
used for optional alignment of the control rules.

00:02:37.416 --> 00:02:40.883
Thanks to to mohESa, a forecast of energy demand

00:02:41.233 --> 00:02:43.316
can be used to plan the use of stored energy

00:02:43.316 --> 00:02:45.333
in a targeted manner.

00:02:45.916 --> 00:02:48.516
This ensures that in the event of a power outage,

00:02:48.883 --> 00:02:51.550
critical processes can continue to run.

00:02:52.350 --> 00:02:55.516
In addition, forecasts of the expected energy

00:02:55.516 --> 00:02:57.633
generation on the following day allow for

00:02:57.633 --> 00:02:59.933
the planning of energy reserve.

00:03:04.416 --> 00:03:07.150
Through bidirectional charging, the battery of

00:03:07.150 --> 00:03:09.516
connected electric vehicles can also be

00:03:09.516 --> 00:03:12.250
used to compensate for a power grid failure,

00:03:12.333 --> 00:03:13.800
together with other local energy

00:03:13.800 --> 00:03:15.416
storage units in the system.

00:03:16.783 --> 00:03:19.216
This makes it possible to keep critical parts

00:03:19.216 --> 00:03:21.816
of the facility running for as long as possible.

00:03:22.816 --> 00:03:25.066
non-essential consumers are deliberately

00:03:25.066 --> 00:03:26.766
throttled in their consumption.

00:03:28.416 --> 00:03:29.916
The electricity generated by

00:03:29.916 --> 00:03:32.383
the photovoltaics is first used to secure

00:03:32.383 --> 00:03:34.300
the consumption of the critical consumers.

00:03:35.100 --> 00:03:37.966
Surplus electricity is used to refill

00:03:37.966 --> 00:03:39.283
the energy storage units.

00:03:43.416 --> 00:03:45.333
Once the power supply from the power grid

00:03:45.333 --> 00:03:49.450
is restored, the energy storage units are filled first.

00:03:49.916 --> 00:03:51.383
Non-essential consumers are

00:03:51.383 --> 00:03:52.950
then brought back online.

00:03:53.450 --> 00:03:55.683
Only when a sufficient charge level of the local

00:03:55.683 --> 00:03:57.550
energy storage units is reached,

00:03:57.983 --> 00:04:01.366
feeding electricity back into the grid will be resumed.